DS-6 PA-Control I and II

ELA monitoring and control devices 

As ELA control units, the DS-6 PA Control I and II combine the control and monitoring of a 100 V PA system with a maximum amplifier power of 2 x 250 W on a DS-6 system.

In its compact 19“ design with one height unit, the units replace a large number of individual components, which all required a great deal of wiring.
A modern sound reinforcement system with DS-6 PA Controls can be wired almost completely with pre-assembled system cables in a pluggable manner.

Depending on the version of the PA-Control, the configuration can be carried out via the control panel with display or the serial interface, or in the case of the PA-Control II only via the serial interface on the unit. A remote solution is also available as an option, in which case the serial interface is integrated into the network via additional components, which are available as accessories.

2 completely independent channels for fully redundant operation, each with two DS-6 Ethernet RJ45 LAN interfaces

Speaker circuit impedance monitoring

Loudspeaker circuit current monitoring

Earth fault monitoring of the loudspeaker cable

Amplifier monitoring with N+1 emergency function

1 or optionally up to 6 zones or speaker circuits per channel can be controlled (12 in total)

Volume reduction at night

Amplifier failure monitoring even during sound reinforcement

No pilot tone monitoring required for automatic switchover to redundant amplifier, no additional power loss at the amplifier

1 or optionally 2 speaker loop monitors

Optional environmental noise-dependent volume control

Network monitoring

Main and secondary fault signalling contact with NC and NO contacts

Depending on the device, RS232 interface for configuration and error message on the front and rear, or control panel with display and RS232 interface for configuration and error message on the rear

Monitored 48V to 60V supply input

By means of integrated software packages, impedance monitoring, amplifier failure, overload and earth fault detection of the sound system can be configured.

As a standard feature, sound reinforcement from one zone or loudspeaker circuit is possible with NEUMANN amplifiers, delivery number 4 172 4 (mono, 1 channel) or 4 171 3 (stereo, 2 channel).

By means of optional additional components which can be integrated into the unit, an extension to up to six zones with the above mentioned monitoring systems is possible. In addition, the cable loops can be monitored in zone one, as well as in the optional zone two, in the case of ring-shaped cabling, and in the event of an interruption, power can be supplied on both sides.

DS-6 PA-Control I and II

3 343 3
3 342 2