DS-22 Uk0 / Up0 / Analogue / PA-Control IP Adapter Gateway

● Connection to the Uk0 adapters 

A connection to the Uk0 outdoor and indoor stations, as well as to the explosion-protected and approved EX-Uk0 outdoor stations, is established via the Uk0 adapters. 


● Connection to the Up0 adapters 

A connection to the Up0 outdoor and indoor stations, as well as to the explosion-protected and approved EX-Up0 adapters.


● Connection to the analogue adapters 

A connection to the analogue outdoor and indoor stations, as well as to the explosion-protected and approved EX analogue outdoor stations, is established via the analogue adapters.


● Connection to the PA Controls 

A connection to the connected loudspeaker circuits is established via the PA Controls with their downstream Class-D amplifiers. All monitoring functions are active and faults are reported to the DS-22 network.


● Fault management via IoT MQTT interface

Fault management in the DS-22 system is carried out via IoT MQTT interface to any MQTT broker, for example the MQTT broker of the DS-22 IP fault indication module.

The DS-22 Uk0 / Up0  / Analogue / PA-Control IP Adapter Gateway is used exclusively in DS-22 systems. It can be connected directly to a DS-22 network node, i.e. a switch.

The DS-22 Uk0 / Up0   / Analogue / PA-Control IP Adapter Gateway is intended for indoor use.

For communication with analogue call stations and digital Uk0 and Up0 call stations from existing networks, the DS-22 Uk0 / Up0  / Analogue / PA-Control IP Adapter Gateway in 19“ design is available as a connecting link to the 1-fold or 8-fold analogue adapters and 8-fold Uk0 or Up0 adapters, also in 19“ design. 

Both the DS-22 Uk0 / Up0 / Analogue / PA-Control IP Adapter Gateway and the adapters can be mounted in the network node and enable ranges to the call stations of up to 6km.

Loudspeaker circuits connected to a PA Control can also be reached and controlled via the DS-22 Uk0 / Up0 / Analogue / PA Control IP Adapter Gateway. All control and monitoring functions of the PA Control are retained and can be communicated to the DS-22 network.

The DS-22 IP fault indication module for rail mounting is available for collecting and forwarding fault indication functions.

DS-22 Uk0 / Up0 / Analogue / PA-Control
IP Adapter Gateway

3 327 5

Technical data and product information may vary or be changed without prior notice.